Finding a fire early helps firefighters avoid dangerous situations and keeps them safe. These systems are specifically designed to find fires when time is still available to evacuate people safely. Alarm systems provide emergency responders with information about the location of the fire so they can speed the process of fire control. This is because early detection mitigates property loss and decreases downtime for the operation.
Alarms are necessary to make any detector useful. They alert at least the building’s occupants and usually notify someone who is on site or off site. Some alarms may directly notify the fire department, but this is typically impractical. Instead, most locations now usually use a staffed monitoring station paired with an alarm.
Automatic sprinklers reduce the risk posed by fires by containing them within small areas and eliminating any dangerous debris. These fire alarm systems have many additional benefits, as seen in the above section. However, they do not remedy the main limitation of these systems: that they can’t extinguish the blaze. Because these devices can act as a heat detection system, they can be used together with notification appliances to create a heat-based notification system. These are not as fast at alerting the building as smoke detectors, which is why facilities with a need for fast notice still require smoke detectors and alarms.
Most fire alarm systems use manual pull stations and only emit a local alarm. They don’t have any detection features and rely on an individual noticing the fire before it’s too late. This can slow down response time significantly. To quickly alert the fire services requires installing a costly system. Plus, the faster a fire is detected, the more expensive it is. An air-aspiring smoke detector system is the most effective at detecting fires; they’re also the cheapest. On the other hand, heat detectors are the slowest to react; they’re also the most expensive.
The fire safety objectives you choose determine the type of fire alarm and detection system you use. These decisions come from a risk assessment of your operations and risks involved in your facility. Choosing an objective also comes down to your willingness to accept risk and the monetary value you place on preserving it.
A fire in a warehouse doesn’t require the same early warning protocols that a hospital does. Hospitals with limited life safety concerns, such as those for patients unable to evacuate on their own, need an early warning system in place. Additionally, dormitories and other facilities where occupants are sleeping when a fire starts need a notification system that works more quickly. Considering the issues in a hospital are different than those in a warehouse is another reason why they need different listed systems.
Alarms in a warehouse where the occupants are awake and aware don’t need to alert early. Since people are typically present in this type of environment, an early warning wouldn’t increase the risk of danger. Additionally, detectors can give slower reaction times without increasing the risk of a fire. This is because the warehouse is unoccupied and life safety isn’t a concern for the occupants.
Before selecting a system, you need to consider the ongoing commitment required with each choice. Maintenance, testing and inspection requirements for these systems are extensive. Supplier maintenance costs typically increase the initial cost of installation, although additional expenses may be incurred as well.
Components that initiate a signal include manual pull stations, detectors and supervisors. In addition, devices that provide a signal include initiating devices.
Pull stations are manual switches that activate the alarm system when operated by building occupants. They’re typically located near routes of travel that building occupants use when exiting the building. Additionally, pull stations should be easy for occupants to locate.
Several different types of detectors come in many different categories. These categories include smoke, flame, and heat detectors. Additional specific types can be found within each of these categories. This specific talk focuses on the most common alarm and detection systems. Each system alerts authorities by activating a fire suppression system.
Different heat sensors come in two main varieties: line and spot. They differ in how they detect heat sources; both are the most basic type of detection devices. Special situations call for line detectors. Spot detectors are more commonly used and tend to be installed in single locations throughout the protected area.
Spot type heat detectors are most commonly combination heat detectors with a particular rate of rise or fixed temperature. These work by rising in temperature at a certain rate, not a specific point. On the other hand, spot type heat detectors with a specific temperature come on only when the surrounding temperature reaches that required mark. Detectors that display a rate-of-rise reading are best suited for use in areas that are typically unheated. These include those mounted on the ceiling in a warehouse without temperature regulation. Detectors mounted at roof level will gradually heat up due to the roof’s naturally high temperature during daylight hours.
There are various types of smoke detectors available. Some use light to sense photoelectricity in the detection chamber. The chamber contains smoke that reflects light entering the room. When this light strikes the photocell, it causes the device to output an indicator.
Ionization smoke detectors measure the charged particles inside smoke. As smoke travels through the chamber, the charged particles are ionized. This allows the plates in the detector to detect any charged particles. Combining smoke and heat sensors in one device is also possible. This option includes beam-type sensors that operate when the laser light is blocked by smoke between the emitter and receiver. Their most common application is in large open spaces.
Air sampling detection systems use pipes with defined lengths placed throughout the protected area. These pipes have small apertures spaced evenly along their length; they continually breathe in air to detect even minuscule levels of combustion byproducts.
Additional fire alarm controls can connect to supervisory devices. These connect to automatic sprinkler systems’ water control valves, for example. Supervisory signals alert people to various problems, such as unauthorized tampering with this valve. Several applications supply this signal, which is closed by the valve’s tamper switch.
Systems can be addressable or nonaddressable. Because of this, all systems have a digital ID that is specific to each detector. A device can communicate individually with the control panel for the fire alarm; non-addressable systems have detectors divided into zones based on wires being in the same pair. However, the control panel doesn’t receive any information about individual detectors.
Addressable systems offer several advantages over non-addressable systems. One advantage is that specific location information is available during a fire. This information is also part of the second advantage of addressable systems: problems with individual components can be identified with trouble signals. When one of a system’s detectors fail such as an addressable system, it will alert the operator with a trouble signal. Alternatively, non-addressable systems will identify the affected area, with a technician needing to check each detector in that area to determine which one isn’t working.
Notifications appliances provide audible, visual, and other means of communication throughout the building. This includes horns, flashing lights, bells and combination units. Certain control panels for fire alarms often allow alarms to be set in certain areas of the building by following the location of the detector that set it off. This can be used to activate staged evacuations, such as in a school.
Adding a communication system to your emergency alarms gives the option of providing specific information and instructions to building occupants. Many people don’t respond correctly when the fire alarm sounds. By installing a voice communication system, people can better understand your instructions during an emergency.